by admin

Inno Setup Serial Number Validation

  1. Inno Setup Wpselecttasks
  2. Inno Setup Download
  3. Registerpreviousdata Innosetup

The Setup program accepts optional command line parameters. These can be useful to system administrators, and to other programs calling the Setup program. /SP-Disables the This will install. Do you wish to continue?

If this is set to yes, Setup will show a User Information wizard page which asks for the user's name, organization and possibly a serial number. The values the. Download game naruto vs one piece vs fairy tail mugen 2014.

  1. If the Setup section directive DisableProgramGroupPage was set to yes, this command line parameter is ignored. Instructs Setup to initially check the Don't create a Start Menu folder check box on the Select Start Menu Folder wizard page. /TYPE=type name. Overrides the default setup type.
  2. Return True to accept the serial number and False to reject it. When using serial numbers, it's important to keep in mind that since no encryption is used and the source code to Inno Setup is freely available, it would not be too difficult for an experienced individual to remove the serial number protection from an installation.

Inno Setup Wpselecttasks

Prompt at the beginning of Setup. Of course, this will have no effect if the DisableStartupPrompt Setup section directive was set to yes. /SILENT, /VERYSILENTInstructs Setup to be silent or very silent. When Setup is silent the wizard and the background window are not displayed but the installation progress window is. When a setup is very silent this installation progress window is not displayed.

Everything else is normal so for example error messages during installation are displayed and the startup prompt is (if you haven't disabled it with DisableStartupPrompt or the '/SP-' command line option explained above).If a restart is necessary and the '/NORESTART' command isn't used (see below) and Setup is silent, it will display a Reboot now? If it's very silent it will reboot without asking. /SUPPRESSMSGBOXESInstructs Setup to suppress message boxes. Only has an effect when combined with '/SILENT' and '/VERYSILENT'.The default response in situations where there's a choice is:. Yes in a 'Keep newer file?'

Situation. No in a 'File exists, confirm overwrite.' Situation. Abort in Abort/Retry situations. Cancel in Retry/Cancel situations.

Yes (=continue) in a DiskSpaceWarning/DirExists/DirDoesntExist/NoUninstallWarning/ExitSetupMessage/ConfirmUninstall situation. Yes (=restart) in a FinishedRestartMessage/UninstalledAndNeedsRestart situation.5 message boxes are not suppressible:. The About Setup message box. The Exit Setup? Message box.

The FileNotInDir2 message box displayed when Setup requires a new disk to be inserted and the disk was not found. Any (error) message box displayed before Setup (or Uninstall) could read the command line parameters. Any message box displayed by Code support function MsgBox./LOGCauses Setup to create a log file in the user's TEMP directory detailing file installation and Run actions taken during the installation process. This can be a helpful debugging aid. For example, if you suspect a file isn't being replaced when you believe it should be (or vice versa), the log file will tell you if the file was really skipped, and why.The log file is created with a unique name based on the current date. (It will not overwrite or append to existing files.)The information contained in the log file is technical in nature and therefore not intended to be understandable by end users.

Nor is it designed to be machine-parseable; the format of the file is subject to change without notice. /LOG=' filename'Same as /LOG, except it allows you to specify a fixed path/filename to use for the log file. If a file with the specified name already exists it will be overwritten.

If the file cannot be created, Setup will abort with an error message. /NOCANCELPrevents the user from cancelling during the installation process, by disabling the Cancel button and ignoring clicks on the close button. Useful along with '/SILENT' or '/VERYSILENT'. /NORESTARTInstructs Setup not to reboot even if it's necessary. /RESTARTEXITCODE= exit codeSpecifies the custom exit code that Setup is to return when a restart is needed. Useful along with '/NORESTART'.

/LOADINF=' filename'Instructs Setup to load the settings from the specified file after having checked the command line. This file can be prepared using the '/SAVEINF=' command as explained below.Don't forget to use quotes if the filename contains spaces. /SAVEINF=' filename'Instructs Setup to save installation settings to the specified file.Don't forget to use quotes if the filename contains spaces. /LANG= languageSpecifies the language to use.

Language specifies the internal name of the language as specified in a Languages section entry.When a valid /LANG parameter is used, the Select Language dialog will be suppressed. /DIR=' x: dirname'Overrides the default directory name displayed on the Select Destination Location wizard page. A fully qualified pathname must be specified. /GROUP=' folder name'Overrides the default folder name displayed on the Select Start Menu Folder wizard page. If the Setup section directive DisableProgramGroupPage was set to yes, this command line parameter is ignored. /NOICONSInstructs Setup to initially check the Don't create a Start Menu folder check box on the Select Start Menu Folder wizard page.

/TYPE= type nameOverrides the default.If the specified type exists and isn't a custom type, then any /COMPONENTS parameter will be ignored. /COMPONENTS=' comma separated list of component names'Overrides the default settings. Using this command line parameter causes Setup to automatically select a custom type.

If no custom type is defined, this parameter is ignored.Only the specified components will be selected; the rest will be deselected.If a component name is prefixed with a '.' character, any child components will be selected as well (except for those that include the dontinheritcheck flag). If a component name is prefixed with a '!' Character, the component will be deselected.This parameter does not change the state of components that include the fixed flag. Example:Deselect all components, then select a parent component and all of its children with the exception of one:/COMPONENTS='.parent,!parentchild'/TASKS=' comma separated list of task names'Specifies a list of that should be initially selected.Only the specified tasks will be selected; the rest will be deselected. Use the /MERGETASKS parameter instead if you want to keep the default set of tasks and only select/deselect some of them.If a task name is prefixed with a '.'

Inno setup compiler

character, any child tasks will be selected as well (except for those that include the dontinheritcheck flag). If a task name is prefixed with a '!'

Character, the task will be deselected. Beginning with Inno Setup 3.0.3, the Setup program may return one of the following exit codes: 0Setup was successfully run to completion.1Setup failed to initialize.2The user clicked Cancel in the wizard before the actual installation started, or chose 'No' on the opening 'This will install.' Message box.3A fatal error occurred while preparing to move to the next installation phase (for example, from displaying the pre-installation wizard pages to the actual installation process). This should never happen except under the most unusual of circumstances, such as running out of memory or Windows resources.4A fatal error occurred during the actual installation process.Note: Errors that cause an Abort-Retry-Ignore box to be displayed are not fatal errors. If the user chooses Abort at such a message box, exit code 5 will be returned.5The user clicked Cancel during the actual installation process, or chose Abort at an Abort-Retry-Ignore box.6The Setup process was forcefully terminated by the debugger ( Run Terminate was used in the IDE).Before returning an exit code of 1, 3, or 4, an error message explaining the problem will normally be displayed.Future versions of Inno Setup may return additional exit codes, so applications checking the exit code should be programmed to handle unexpected exit codes gracefully. Any non-zero exit code indicates that Setup was not run to completion.

Serial

The uninstaller program (unins???exe) accepts optional command line parameters. These can be useful to system administrators, and to other programs calling the uninstaller program. /SILENT, /VERYSILENTWhen specified, the uninstaller will not ask the user for startup confirmation or display a message stating that uninstall is complete. Shared files that are no longer in use are deleted automatically without prompting. Any critical error messages will still be shown on the screen. When '/VERYSILENT' is specified, the uninstallation progress window is not displayed.If a restart is necessary and the '/NORESTART' command isn't used (see below) and '/VERYSILENT' is specified, the uninstaller will reboot without asking.

/SUPPRESSMSGBOXESInstructs the uninstaller to suppress message boxes. Only has an effect when combined with '/SILENT' and '/VERYSILENT'. See '/SUPPRESSMSGBOXES' under for more details. /LOGCauses Uninstall to create a log file in the user's TEMP directory detailing file uninstallation and UninstallRun actions taken during the uninstallation process.

Inno Setup Download

This can be a helpful debugging aid.The log file is created with a unique name based on the current date. (It will not overwrite or append to existing files.)The information contained in the log file is technical in nature and therefore not intended to be understandable by end users. Nor is it designed to be machine-parseable; the format of the file is subject to change without notice. /LOG=' filename'Same as /LOG, except it allows you to specify a fixed path/filename to use for the log file. If a file with the specified name already exists it will be overwritten. If the file cannot be created, Uninstall will abort with an error message.

Registerpreviousdata Innosetup

/NORESTARTInstructs the uninstaller not to reboot even if it's necessary. Beginning with Inno Setup 4.0.8, the uninstaller will return a non-zero exit code if the user cancels or a fatal error is encountered. Programs checking the exit code to detect failure should not check for a specific non-zero value; any non-zero exit code indicates that the uninstaller was not run to completion.Note that at the moment you get an exit code back from the uninstaller, some code related to uninstallation might still be running.

Because Windows doesn't allow programs to delete their own EXEs, the uninstaller creates and spawns a copy of itself in the TEMP directory. This 'clone' performs the actual uninstallation, and at the end, terminates the original uninstaller EXE (at which point you get an exit code back), deletes it, then displays the 'uninstall complete' message box (if it hasn't been suppressed with /SILENT or /VERYSILENT).